Advisory

CVE-2026-123890: Critical Authentication Bypass in VMware vCenter (CVSS 9.8)

A critical authentication bypass flaw (CVE-2026-123890) in the VMware Directory Service allows an unauthenticated attacker with network access to VMware vCenter to bypass authentication entirely and gain unauthorized access to the system. With a CVSS score of 9.8 and confirmed active exploitation tracked by CISA, this vulnerability demands immediate attention from every organization running affected vCenter or Telco Cloud versions.

TL;DR: Apply Broadcom's patched builds immediately — vCenter 9.1.1.0200, 9.0.2.0200, 8.0 U3m, or 5.2.5 as appropriate — and consult KB463116 for Telco Cloud guidance. This vulnerability is in the CISA Known Exploited Vulnerabilities catalog; treat remediation as urgent.

What Is the Flaw?

CVE-2026-123890 is an authentication bypass vulnerability classified under CWE-288 — Authentication Bypass Using an Alternate Path or Channel. The flaw resides in the VMware Directory Service, a core component of VMware vCenter.

In practical terms, the vulnerability allows an attacker who has network-level access to a vCenter endpoint to reach authenticated functionality without supplying valid credentials. The attacker does not need to know any password, hold any existing account, or interact with a victim user. The CVSS 3.1 vector AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H captures this precisely: the attack is network-reachable, requires low complexity, needs no privileges, and requires no user interaction, while delivering full confidentiality, integrity, and availability impact.

CISA added this CVE to the Known Exploited Vulnerabilities (KEV) catalog on 2026-11-20, indicating that exploitation in the wild has been confirmed.

Who and What Is Affected?

The following Broadcom VMware vCenter versions are confirmed affected:

  • vCenter 9.1.x — fixed in 9.1.1.0200
  • vCenter 9.0.x — fixed in 9.0.2.0200
  • vCenter 8.0 — fixed in 8.0 U3m
  • vCenter 5.x — fixed in 5.2.5

In addition, the following Broadcom Telco Cloud products are affected; organizations running them should consult Broadcom KB463116 for specific guidance:

  • Telco Cloud Platform 3.0, 4.x, 5.0.x, 5.1.x, and 5.2
  • Telco Cloud Infrastructure 3.0

Any organization with an internet-exposed or network-accessible vCenter or Telco Cloud deployment running an unpatched version should treat this as a critical priority.

What Is the Potential Impact?

vCenter Server is the central management plane for VMware virtualized environments. Unauthorized access to it typically provides an attacker with broad control over all managed hosts, virtual machines, storage, and networking configurations.

Because the bypass requires no credentials and no user interaction, the barrier to exploitation is exceptionally low for any attacker who can reach the service over a network. The CVSS 3.1 score of 9.8 (CRITICAL) reflects high impact across all three security pillars:

  • Confidentiality: An attacker may access sensitive configuration data, credentials stored within the environment, and workload data.
  • Integrity: An attacker with unauthorized access to vCenter can modify virtual machine configurations, deploy new workloads, or alter infrastructure settings.
  • Availability: Disruption or deletion of virtual machines and infrastructure components is feasible once the management plane is compromised.

CISA's KEV entry confirms that exploitation of this vulnerability is occurring in the wild. The required remediation action references CISA's Binding Operational Directive (BOD) 26-04 and includes forensic triage requirements, which signals that defenders should not only patch but also investigate for potential prior compromise.

What to Do Now

The following prioritized steps reflect guidance from Broadcom and CISA:

  1. Identify all affected instances. Inventory every vCenter deployment and Telco Cloud instance across your environment, including those not directly internet-facing but reachable from networks that could be laterally traversed.
  2. Apply vendor patches immediately. Upgrade to the fixed build for your installed version: 9.1.1.0200, 9.0.2.0200, 8.0 U3m, or 5.2.5. For Telco Cloud products, follow Broadcom KB463116.
  3. Restrict network access. Until patching is complete, restrict access to vCenter management interfaces to trusted administrative networks and VPNs. Remove any direct internet exposure.
  4. Conduct forensic triage. CISA's KEV required action specifically references forensic triage requirements. Because exploitation is confirmed in the wild, organizations should review authentication logs, privileged account activity, and vCenter event logs for anomalies that may indicate prior unauthorized access — even before patching is complete.
  5. Follow BOD 26-04 guidance. Federal civilian agencies are subject to CISA's Binding Operational Directive 26-04. All organizations should use this directive as a remediation timeline benchmark.
  6. Discontinue use if patching is unavailable. CISA advises that if mitigations cannot be applied, affected product use should be discontinued. This applies particularly to any Telco Cloud configurations where vendor guidance is still pending.

Primary references: NVD entry for CVE-2026-123890, CISA KEV Catalog, and Broadcom KB463116.

How External Security Testing Can Surface This Exposure

Organizations often do not have complete visibility into which vCenter or management-plane interfaces are reachable from outside their intended trust boundaries. External, attacker-perspective testing helps close that gap.

Point-in-time external vulnerability scanning of your internet-facing and perimeter-adjacent assets can identify:

  • vCenter service banners or version fingerprints that indicate an unpatched build is exposed to untrusted networks.
  • Management ports and interfaces that should be restricted but are accessible from external IP ranges.
  • Misconfigurations in network segmentation that place vCenter within reach of less-trusted network segments.

Because this vulnerability requires only network access — no credentials — detecting its exposure is fundamentally a question of network reachability. If a scanner or an attacker can reach the VMware Directory Service on an unpatched vCenter, the authentication bypass is potentially exploitable. Verifying that patched versions are in place and that management interfaces are not externally reachable are the two most important external validation checks for this CVE.

Internal segmentation reviews should also confirm that lateral movement from lower-trust zones (such as a DMZ or a compromised workstation) cannot reach vCenter endpoints.

Sources & further reading: NVD CVE-2026-123890 and the CISA KEV catalog are the authority on affected and fixed versions. Vendor/independent analysis: support.broadcom.com, cloud.google.com, cisa.gov. This advisory contains no exploit code.

Frequently asked questions

Does an attacker need an existing account or any credentials to exploit CVE-2026-123890?

No. According to both the NVD description and the CISA KEV entry, the vulnerability allows an unauthenticated attacker with network access to vCenter to bypass authentication entirely. No existing account, password, or user interaction is required.

Is this vulnerability being actively exploited?

Yes. CISA added CVE-2026-123890 to the Known Exploited Vulnerabilities catalog on 2026-11-20, which indicates that exploitation in the wild has been confirmed. CISA's required action also specifically includes forensic triage steps, suggesting defenders should investigate for potential prior compromise in addition to patching.

My vCenter is not directly on the internet — am I still at risk?

Restricting internet exposure reduces risk but does not eliminate it. The CVSS vector indicates the attack is network-reachable, meaning any network path to the vCenter service — including internal networks, VPNs, or lateral movement from a compromised adjacent system — could be used. Network segmentation is an important compensating control, but patching remains the definitive remediation.

What should I do if I cannot patch immediately?

Broadcom and CISA advise applying vendor mitigations in accordance with vendor instructions. If mitigations cannot be applied, CISA's guidance indicates organizations should consider discontinuing use of the affected product. As an interim measure, restricting network access to vCenter management interfaces to only trusted, explicitly authorized administrative systems reduces the attack surface while patching is arranged.